WARNING
DO NOT PLACE PLASTIC BOWL UNIT IN SERVICE
WITHOUT METAL BOWL GUARD INSTALLED
Plastic bowl units are sold only with metal bowl guards. To minimize the danger of flying fragments in the
event of plastic bowl failure, the metal bowl guards should not be removed. If the unit is in service without
the metal bowl guard installed, manufacturer's warranties are void, and the manufacturer assumes no
responsibility for any resulting loss.
IF UNIT HAS BEEN IN SERVICE AND DOES NOT HAVE A METAL BOWL GUARD, ORDER ONE AND
INSTALL BEFORE PLACING BACK IN SERVICE..
For information on materials harmful to plastic bowls, contact a Mobay Chemical or General Electric office for infor-
mation regarding materials that will attack polycarbonate plastic.
CAUTION
Certain compressor oils, chemicals, household cleaners, solvents, paints and fumes will attack plastic
bowls and can cause bowl failure. Do not use near these materials. When bowl becomes dirty replace bowl
or wipe only with clean, dry cloth. Reinstall metal bowl guard or buy and install a metal bowl guard.
Immediately replace any crazed, cracked, damaged or deteriorated plastic bowl with a metal bowl or a new
plastic bowl and metal bowl guard.
CAUTION
EXCEPT as otherwise specified by the manufacturer, this product is specifically designed for com-
pressed air service, and use with any other fluid (liquid or gas) is a misapplication. For example, use
with or injection of certain hazardous liquids or gases in the system (such as alcohol or liquid petroleum
gas) could be harmful to the unit or result in a combustible condition or hazardous external leakage.
Manufacturer's warranties are void in the event of misapplication, and manufacturer assumes no
responsibility for any resulting loss. Before using with fluids other than air, or for non-industrial applica-
tions, or for life support systems consult manufacturer for written approval.
O-RING
METAL BOWL
GUARD
(optional)
TRANSPARENT
PLASTIC
BOWL
(Includes Bowl
O-Ring)
SILICA GEL
BODY
NNR
NNR=NOT NORMALLY REPLACED
Some of the materials that will attack
polycarbonate plastic bowls.
Acetaldehyde Chlorobenzene Methylene chloride
Acetic acid (conc.) Chloroform Methylene salicylate
Acetone Cresol Milk of lime (CaOH)
Acrylonitrile Cyclohexanol Nitric acid (conc.)
Ammonia Cyclohexanone Nitrobenzene
Ammonium fluoride Cyclohexene Nitrocellulose lacquer
Ammonium hydroxide Dimethyl formamide Phenol
Ammonium sulfide Diozane Phosphorous hydroxy
Anaerobic adhesives Ethane tetrachloride chloride
and sealants Ethyl acetate Phosphorous trichloride
Antifreeze Ethyl ether Propionic acid
Benzene Ethylamine Pyridine
Benzoic acid Ethylene chlorohydrin Sodium hydroxide
Benzyl alcohol Ethylene dichloride Sodium sulfide
Brake fluids Ethylene glycol Styrene
Bromobenzene Formic acid (conc.) Sulfuric acid (conc.)
Butyric acid Freon (refrig. & propell.) Sulphural chloride
Carbolic acid Gasoline (high aromatic) Tetrahydronaphthalene
Carbon disulfide Hydrazine Tiophene
Carbon tetrachloride Hydrochloric acid (conc.) Toluene
Caustic potash solution Lacquer thinner Turpentine
Caustic soda solution Methyl alcohol Xylene
Perchlorethylene
and others
Trade names of some compressor oils, rubber compounds and
other materials that will attack polycarbonate plastic bowls.
Atlas "Perma-Guard" National Compound #N11
Buna N "Nylock" VC-3
Cellulube #150 and #220 Parco #1306 Neoprene
Crylex #5 cement *Permabond 910
*Eastman 910 Petron PD287
Garlock #98403 (polyurethane) Prestone
Haskel #568-023 Pydraul AC
Hilgard Co.'s hil phene Sears Regular Motor Oil
Houghton & Co. oil#1120.#1130 & #1055 Sinclair oil "Lily White"
Houtosafe 1000 Stauffer Chemical FYRQUEL #150
Kano Kroil Stillman #SR 269-75 (polyurethane)
Keystone penetrating oil #2 Stillman #SR 513-70 (neoprene)
*Loctite 271 Tannergas
*Locite 290 Telar
*Loctite 601 Tenneco anderol #495 & #500 oils
Loctite Teflon-Sealant Titon
Marvel Mystery Oil *Vibra-tite
Minn. Rubber 366Y Zerex
*When in raw liquid form.
We cannot possibly list all harmful substances, so check with Mobay or
the General Electric office for further information on polycarbonate plastic.
(see reverse side for Installation and Maintenance Instructions)
INSTALLATION AND
MAINTENANCE SHEET
Moisture Indicator X05
with Variations and Accessories
83-303-000 REV REL 8/95
Printed in the U.S.A.
®
OPERATIONS
Page view 0
1 2

Summary of Contents

Page 1 - MAINTENANCE SHEET

WARNINGDO NOT PLACE PLASTIC BOWL UNIT IN SERVICEWITHOUT METAL BOWL GUARD INSTALLEDPlastic bowl units are sold only with metal bowl guards. To minimize

Page 2

INSTALLATION1.Refer to the warning.2.Install downstream of dryer or where required.3.Install the unit with the airflow in direction of arrow.4.Silica

Comments to this Manuals